Reliability testing standards
LCD display screens are widely used in various fields, and different fields have different requirements for display screens. In order to ensure the stable use of products, reliability tests are carried out.
How many tests are there for the display?
The test of the display screen is generally divided into two types: mechanical test, environmental test and optical test. General test items for mechanical test: drop test, pressure test, etc., environmental test: high temperature and high humidity, thermal shock, etc. Optical test items: display brightness, color coordinates, color gamut, gamma, etc. Through different tests to confirm that our products can run stably for a long time on your equipment.
If you have special testing requirements, please contact us
Reliability Test Conditions
No. | test item | Condition | quantity |
1 | (Low temperature activiation test) | chamber ·T=-10℃,72H | 3pcs |
2 | (High temperature & operation test) | chamber ·T=50℃,72H ,85%RH | 3pcs |
3 | (Low temperature storage test) | chamber ·T=-20℃,72H | 3pcs |
4 | (High temperature storage test) | chamber ·T=70℃,72H ,85%RH | 3pcs |
5 | (Thermal shock test) | ·High temperature 70°C/60min ·Low temperature -20°C/60min ·Transition in 5min ·Cycle: 20 cycles | 3pcs |
6 | Temperature Cycle Test | chamber ·T=70℃,72H ,85%RH | 3pcs |
7 | (Hot start) | chamber ·T =+50℃ @ 85%RH, ·50 cycle | 3pcs |
8 | (Cold Start) | chamber ·T =-10℃ ·50 cycle | 2pcs |
9 | Hot wake up and sleep test | chamber ·T =+50℃ @ 85%RH, ·50 cycle wake up | 3pcs |
10 | Cold wake up and sleep test | chamber ·T =-10℃ ·50 cycle wake up camera | 2pcs |